Certex Logo

Categories

Palmer Safety Guardrail System

Palmer Safety Guardrail System

Guardrail System may be used in Fall Prevention applications ONLY. Fall Prevention Systems are placed around the leading edges of any and all fall hazards to prevent a worker from going over an edge, and may be used in substitute of Fall Protection or safety netting systems. Installation requirements for Guardrail System set forth in product instruction manual MUST be adhered to. Personal Fall Arrest, Work Positioning, Climbing, Rescue, and any other systems must NEVER be connected to Fall Prevention Systems.

Meets or exceeds all OSHA 1910 General Industry Standards and OSHA 1926 Subpart M Construction Standard.

ALWAYS assemble and use Guardrail System according to instructions provided with equipment by the manufacturer.

Materials:
Guardrail & 4-way Baseplate – Powder Coated Steel
Knuckle & 2-way Baseplates – Galvanized Steel

Fall Prevention: Guardrail System may be used in Fall Prevention applications ONLY. Fall Prevention Systems are placed around the leading edges of any and all fall hazards to prevent a worker from going over an edge, and may be used in substitute of Fall Protection or safety netting systems. Installation requirements for Guardrail System set forth in product instruction manual MUST be adhered to. Personal Fall Arrest, Work Positioning, Climbing, Rescue, and any other systems must NEVER be connected to Fall Prevention Systems.

MAXIMUM permitted roof pitch is 1/12 (5º).Toeboards must be 2” x 4” construction grade lumber. Baseplates must be at least 24” from the edge of any opening or leading edge hazard.

An outrigger is a guardrail installed perpendicular to a continuous run. ALWAYS use outriggers at BOTH ends of any interruption in a Guardrail System, and at BOTH ends of a continuous Guardrail System. There is no limit on the maximum length of a continuous Guardrail System.

 

Part # Size Weight Description
GUARDRAIL5 42”H x 5’L 27 lbs. 5’ Guardrail
GUARDRAIL6 42”H x 6’L 31 lbs. 6’ Guardrail
GUARDRAIL8 42”H x 8’L 39 lbs. 8’ Guardrail
GUARDRAIL10 42”H x 10’L 47 lbs. 10’ Guardrail
GUARDRAIL12 42”H x 12’L 54 lbs. 12’ Guardrail
GUARDRAILKNUCKLE 8.5”H x 5’L 3 lbs. Used with Palmer Safety Guardrail System. Galvanized Steel, Complete with a set of two screws.
GUARDRAIL2WBASE 10”W x 30”L 70 lbs. Guardrail Baseplate 2 Way
GUARDRAIL4WBASE 21-1/2”W x 21-1/2”L 77 lbs. Guardrail Baseplate 4 Way

Palmer Safety Guardrail System Palmer Safety Guardrail System 2W Base Palmer Safety Guardrail System Guardrail Knuckle Palmer Safety Guardrail System 4W Base

Meets or exceeds all OSHA 1910 General Industry Standards and OSHA 1926 Subpart M Construction Standard.

ALWAYS assemble and use Guardrail System according to instructions provided with equipment by the manufacturer.

Materials: Guardrail & 4-way Baseplate – Powder Coated Steel Knuckle & 2-way Baseplates – Galvanized Steel

Fall Prevention: Guardrail System may be used in Fall Prevention applications ONLY. Fall Prevention Systems are placed around the leading edges of any and all fall hazards to prevent a worker from going over an edge, and may be used in substitute of Fall Protection or safety netting systems. Installation requirements for Guardrail System set forth in product instruction manual MUST be adhered to. Personal Fall Arrest, Work Positioning, Climbing, Rescue, and any other systems must NEVER be connected to Fall Prevention Systems.

MAXIMUM permitted roof pitch is 1/12 (5º).

Toeboards must be 2” x 4” construction grade lumber. Baseplates must be at least 24” from the edge of any opening or leading edge hazard.

An outrigger is a guardrail installed perpendicular to a continuous run. ALWAYS use outriggers at BOTH ends of any interruption in a Guardrail System, and at BOTH ends of a continuous Guardrail System. There is no limit on the maximum length of a continuous Guardrail System.

Palmer Safety Guardrail System Dimensions

WARNING: Prop 65: Products supplied by CERTEX USA may expose you to chemicals including Nickel, which is known to the State of California to cause cancer. For more information, visit to www.P65Warnings.ca.gov.

Related Products

Modulift MOD 400/600 Spreader Beam

Modulift MOD 400/600 Spreader Beam

The Modulift Spreader is modular in length, and every spreader consists of 1 pair of End Units and Drop Links, with intermediate struts that can be bolted into the assembly to achieve different spans. MOD 400/600 has an assembled span ranging from 6ft to 78ft in 1ft...

Modulift MOD 400/500 Spreader Beam

Modulift MOD 400/500 Spreader Beam

The Modulift Spreader is modular in length, and every spreader consists of 1 pair of End Units and Drop Links, with intermediate struts that can be bolted into the assembly to achieve dierent spans. MOD 400/500 has an assembled span ranging from 6ft to 78ft in 1ft...

Modulift MOD 400/400 Spreader Beam

Modulift MOD 400/400 Spreader Beam

The Modulift Spreader is modular in length, and every spreader consists of 1 pair of End Units and Drop Links, with intermediate struts that can be bolted into the assembly to achieve dierent spans. MOD 400/400 has an assembled span ranging from 6ft to 78ft in 1ft...

Modulift MOD 250/400 Spreader Beam

Modulift MOD 250/400 Spreader Beam

The Modulift Spreader is modular in length, and every spreader consists of 1 pair of End Units and Drop Links, with intermediate struts that can be bolted into the assembly to achieve dierent spans. MOD 250/400 has an assembled span ranging from 6ft to 68ft in 1ft...